VeinDirectory.org

 

 
 
 
 

Pharmacomechanical Thrombolysis near Taneytown, MD (Maryland)

Center for Vein Restoration
7300 York Road
Suite LL
Towson, Maryland 21204
Distance: 33.93 Miles
Contact/Email Doctor
Toll Free: 410-928-7097


Center for Vein Restoration
11085 Little Patuxent Parkway S, Suite 203
Columbia, Maryland 21044
Distance: 35.36 Miles
Contact/Email Doctor
Toll Free: 301-358-6410


Center for Vein Restoration
19785 Crystal Rock Dr., Suite 310
Germantown , Maryland 20874
Distance: 35.79 Miles
Contact/Email Doctor
Toll Free: 301-678-9953


Center for Vein Restoration
1119 Rockville Pike
Suite #210
Rockville, Maryland 20852
Distance: 43.72 Miles
Contact/Email Doctor
Toll Free: 301-859-4157


Center for Vein Restoration
1600 Crain Highway
Suite 408
Glen Burnie, Maryland 21061
Distance: 45.18 Miles
Contact/Email Doctor
Toll Free: 410-449-4385


Vein Disease Clinic
1401 Madison Park Drive
Glen Burnie, Maryland 21061
Distance: 45.18 Miles
Contact/Email Doctor
Toll Free: 410-881-5689


Center for Vein Restoration
831 University Blvd. East
Suite 24-25
Silver Spring, Maryland 20903
Distance: 46.4 Miles
Contact/Email Doctor
Toll Free: 301-678-8966


Center for Vein Restoration
2225 Old Emmorton Road, Suite 110
Bel Air, Maryland 21015
Distance: 47.28 Miles
Contact/Email Doctor
Toll Free: 410-609-3284


Center for Vein Restoration
7300 Hanover Drive
Suite 104
Greenbelt, Maryland 20770
Distance: 49.34 Miles
Contact/Email Doctor
Toll Free: 301-850-2107




About Pharmacomechanical Thrombolysis

Pharmacomechanical thrombolysis is a 30-minute outpatient procedure which is used to remove clots located in the deeper veins of the body. The technique uses two modalities: application of clot-dissolving agents directly to the clot and mechanical maceration to help break the clot apart. The mechanical motion also allows for a more thorough dispersion of the clot-dissolving agent, helping to soften the clot and prepare it for removal.

Traditional thrombolysis techniques rely solely on the use of these clot-dissolving agents to slowly dissolve clots over several hours to several days. By contrast, pharmacomechanical thrombolysis can remove clots within a few moments, requiring far less potentially harmful clot-dissolving agents than traditional thrombolysis. As a result, recovery is shorter with pharmacomechanical thrombolysis and the technique is associated with a lower risk of bleeding and other complications.

The pharmacomechanical thrombolysis technique itself is usually performed under sedation, and begins with the insertion of a long, flexible catheter into the vein that contains the clot. The catheter is advanced through the vein until it emerges on the far side of the clot. Tiny balloons located on either side of the clot are inflated to securely partition the clot from the rest of the bloodstream. Once these tiny balloons are successfully inflated, clot-dissolving agents can be safely administered directly to the area and the clot can be mechanically broken down into tiny pieces. These tiny bits are aspirated through the hollow end of the catheter. After the material is cleared, the balloons are deflated and the catheter is removed from the body. Recovery is brief, and most individuals can resume normal activity shortly after the procedure.


Learn more about Pharmacomechanical Thrombolysis

Copyright © 2014 HealthNews.org. All rights reserved. Privacy Policy
Do not use this website as a substitute for medical care. Please consult your physician
or other medical care provider regarding any medical questions you may have.